DCLDD1

DCLDD1

Water level regulator inside the boiler, activating the pump when necessary.

The controller is able to manage and monitor the presence of water inside the boiler and activating the pump when necessary.

FUNCTIONS

Loading cycle of a boiler with one level probe:
The loading function regulates and controls the correct level of water in the boiler. If the level probe in not covered by water, then the pump and solenoid valveoutput are simultaneously activated. When the probe is reached by water, the pump and solenoidvalveoutputare deactivated and remain switched off until the status of the probechanges again.

Loading time-out:
The loading function remains activated for a maximum of 150 seconds (so called time-out). After this period of time the pump and solenoid valve output are deactivated in order to protect the machine from eventual breaks or malfunctioning.

TECHNICAL FEATURES

TECHNICAL FEATURESDETAILS
Power Supply: 230 Vac ± 10% 50/60 Hz
  115 Vac ± 10% 50/60 Hz
High voltage Input Double pump output - 2x8A / 250 VAC Resistive
High voltage Output level probe whit conductivity detection
Low voltage input NP
Low voltage Output NP
Bow Dimension 73,5 mm x 45,4 mm x 75 mm
Operating Conditions 0...+50°C con Umidità Relativa:30...85% (senza condensa)
Storage Conditions -20...+80°C con Umidità Relativa:30...85% (senza condensa)
Box Material PVC V0
Connection type male faston connector 6,3 - male connector 2,54mm pitch
Assembly type Panel fixing wiht a maximum diameter 3,8mm

Questo sito utilizza cookie, anche di terze parti, per migliorare la tua esperienza e offrire servizi in linea con le tue preferenze. Chiudendo questo banner, scorrendo questa pagina o cliccando qualunque suo elemento acconsenti all’uso dei cookie. Se vuoi saperne di più o negare il consenso a tutti o ad alcuni cookie vai alla sezione